Oil-type transformer is one of the important equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It reduces the 10(6)kV or 35kV network voltage to the 230/400V bus voltage used by users. This type of product is suitable for AC 50 (60) Hz, three-phase oil-type transformer with a maximum rated capacity of 2500kVA (single-phase maximum rated capacity is 833kVA, single-phase transformers are generally not recommended), and can be used indoors (outdoors) with a capacity of 315kVA and below, it can be installed on the pole. The ambient temperature is not higher than 40℃ and not lower than -25℃. The maximum daily average temperature of the oil-type transformer is 30℃, the maximum annual average temperature is 20℃, and the relative humidity does not exceed 90% (ambient temperature 25℃), the altitude does not exceed 1000m. If it is inconsistent with the above conditions of use, appropriate quota adjustments should be made according to the relevant provisions of GB6450-86.
Industry-Specific Attributes
| Use | Power |
| Phase | Three |
| Coil Structure | TOROIDAL |
| Coil Number | AUTOTRANSFORMER |
Other Attributes
| Place of Origin | Shandong, China |
| Brand Name | Jinshida |
| Model Number | SCB11-30~1600/,S11-30~1600 |
| Input Voltage | 10kv |
| Product name | Three Phase Transformer |
| Rated capacity | 400kVA |
| Frequency | 50Hz/60Hz |
| Standard | ISO9001: 2008 |
| Name | High Fequency Transformer |
| Rated voltage | 22KV |
| Warranty | 24 Months |
| Capacity | 400kva |
| Cooling Method | ONAN |
Packaging and Delivery
Selling Units |
Single item |
Single package size |
1260X820X1240 cm |
Single gross weight |
50.000 kg |
10 Rated Power (kVA) | High Voltage (kv) | Low Voltage (kv) | Connection symbole | No-load loss(W) | On-load loss(W) | No load current (%) |
30KVA | 6.3KV 15KV 22KV 25KV 33KV 10KV 11KV 20KV 35KV | 0.4 | Ydn11 Yyno | 570 | 4300 | 0.4 |
50KVA |
80KVA | 680 | 5140 | 0.45 |
100KVA |
125KVA | 810 | 30800 | 0.4 |
160KVA |
200KVA | 980 | 7500 | 0.4 |
250KVA |
315KVA | 1150 | 10300 | 0.35 |
400KVA |
500KVA | 1360 | 12000 | 0.3 |
630KVA |
800KVA | 1640 | 145000 | 0.6 |
1000KVA |
1250KAV | 1950 | 19140 | 0.6 |
1600KVA |
2000KVA | 2340 | 22220 | 0.5 |
2500KAV |
Customized Various Models
![Customized Various Models Customized Various Models]()
Product Process
![product process product process]()
Product Accessories
![product accessories product accessories]()
Application
Our products can be used in various industries such as power industry, urban construction, ports, etc.
![application application]()
Certificate
![certificate certificate]()
Packing and Delivery
![packing and delivery packing and delivery]()
About Us
Shandong Jinshida Transformer Co., Ltd. is the unique service provider of power transmissionand distribution equipment in electrical industry since 2001, covering an area of 80000 m2among 50000 m2 modern workshop with 600 unit advanced production equipment. By operating with industrial partners and contractors, Jinshida Electric has an establishedinternational network in more than 40 counties. Jinshida Electric is devoted to provide safe, high efficient and intelligent power transformation and distribution solution, focusing on R&D, manufacturing, sales and service.
Rated Voltage: up to 40.5kV
Rated Capacity: 50kVA up to 26.5MVAX 33kV class and below Amorphous Alloy Dry Type TransformerX33kV class and below Substation Transformer 33kV class and below Oil-immersed Transformer 220kV class and below Oil-immersed Transformer Covering different application: power grid, solar power plant, wind power plant, Hydro powerplant, nuclear power plant, railway, telecommunication, infrastructure, real estate.
![Company Profile Company Profile]()
Our Advantages
1.Quality Assurance
Jinshida follows the standard ofcustomer demand, providing technical support and full quality control supervision to ensure that our products have excellent quality and reliability.
2.After-sales guarantee
Jinshida provides global customers with worry-free after-sales service, athree-year warranty period to allow customers to enjoy long-term stability of performance, to ensure that customers in the process of use can be satisfied with the experience.
3.Delivery time guarantee
Jinshida strictly adheres to the contractual delivery date to ensure that customers can receive the required products on time.
FAQ
1.On site/on line Production and Quality production supervision. Customer own the product supervision right, and for each important process during the manufacturing andtesting lor to be defined by customer's request, by means of on site check or on line check. Meanwhile, we valso provide traceable records for check.
2.Packing&Transportation Wooden pallet packing or or to be defined by customer.
3. Leading time
For standard product, approximately 15 working days before delivery.
For customized product, approximately 20~30 working days before delivery.
Order quantity/customization requirements can also affect the leading time.
4. Warranty/ Payment terms
2 years of warranty at least.
For the first order we normally accept T/T, 30%+70%. Regular customer payment terms to be negotiated by both parties.
5.Difference Between Power Transformer and Distribution Transformer
(1)Transformer Size / insulation Level:Power transformers have a higher insulation level than distribution transformers
(2)lron Losses and Copper Losses:Power transformers lose energy as heat due to eddy current losses in their steel laminations and hysteresis losses in the core material. Distribution transformers don't have any iron part so they have lower iron losses than power transformers, They also lose energy due to hvsteresis losses in thecore material.
(3)Maximum Efficiency: Power transformers are generally less efficient than distribution transformers because their larger size and heavier currents.
![jsd jsd]()