Single Phase Oil Immersed Power Transformer 1000kva

 It adopts radiator oil tank of corrugated shteet type or expansion type. As it doesn't need oil conservator, the height of transformer is reduced, and as the transformer oil doesn't contract with air, the oil ageing is retarded, thus prolonging the service life of transformer.

Product Details

The performances of model S9-M, S10-M, S11-M 10kv-35KV series full-sealed oil-immersed distribution transformes conform to Standards lEC lEEE. lts core is made of quality cold-rolled silicon sheet andis of a full-miter non-puncture structure and its coil is made of quality oxygen-free copper.


Single Phase Oil Immersed Power Transformer 1000kva

Product Advantages

It adopts radiator oil tank of corrugated shteet type or expansion type.

As it doesn't need oil conservator, the height of transformer is reduced, and as the transformer oil doesn't contract with air,the oil ageing is retarded, thus prolonging the service life of transformer.

The no-load loss of Model S10-M is 20% lower thanthat of Model S9-M,and S11-M is 30% lower than S9-M.


Single Phase Oil Immersed Power Transformer 1000kva

Industry-Specific Attributes

UsePower
PhaseSingle
Coil StructureTOROIDAL
Coil NumberAUTOTRANSFORMER


Other Attributes


Place of OriginShandong, China
Brand NameJinshida
Model NumberSCB11-30~1600/,S11-30~1600/,S11-30~20000/35
Product nameOil Immersed Power Transformer
Frequency50Hz/60Hz
Rated capacity400kVA
StandardISO9001: 2008
NameOil Immersed Distribusion Transformer
Rated voltage22KV
Warranty24 Months
Cooling MethodONAN
Capacity400kva
Transformer typeS11 Oil-immersed Transformer


Packaging and Delivery

Selling Units


Single item


Single package size


1260X820X1240 cm


Single gross weight


50.000 kg


Product Paramenters

10 Rated Power (kVA)

High Voltage (kv)

Low Voltage (kv)

Connection symbol

No-load loss(W)

On-load loss(W)

No load current (%)

30KVA

6.3KV

15KV

22KV

25KV

33KV

10KV

11KV

20KV

35KV

 

0.4

Ydn11

Yyno

570

4300

0.4

50KVA

80KVA

680

5140

0.45

100KVA

125KVA

810

30800

0.4

160KVA

200KVA

980

7500

0.4

250KVA

315KVA

1150

10300

0.35

400KVA

500KVA

1360

12000

0.3

630KVA

800KVA

1640

145000

0.6

1000KVA

1250KAV

1950

19140

0.6

1600KVA

2000KVA

2340

22220

0.5

2500KAV


Customized Various Models


various models

various models



Product Process


product process

Application

Our products can be used in the power industry, mining industry, aviation industry, petroleum industry, bridge engineering, etc.

application



Certificate

certificate


Packing and Delivery


packing and delivery

About Us

China's JinShiDa has 21 years of experience in international power projects, helping many customers around the world to complete power projects. For example, Canada.Mexico, Panama, Ecuador, Guatemala, Honduras, Chile, El Salvador, Australia, New Zealand, Spain, Belgium, Algeria, South Africa, Ethiopia, Myanmar, Kazakhstan, etc.Kingstar also has a very good after-sales installation service team abroad, so if you have transformer needs, you can contact us.


Company Profile


Our Advantages

1.Quality Assurance

Jinshida follows the standard of customer demand, providing technical support and full quality control supervision to ensure that our products have excellent quality and reliability.

2.After-sales guarantee

Jinshida provides global customers with worry-free after-sales service, at three-year warranty period to allow customers to enjoy long-term stability of performance, to ensure that customers in the process of use can be satisfied with the experience.

3.Delivery time guarantee

Jinshida strictly adheres to the contractual delivery date to ensure that customers can receive the required products on time.


FAQ

1.On site/on line Production and Quality production supervision.Customer own the product supervision right, and for each important process during the manufacturing and testing (or to be defined by customer's request), by means of on site check or on line check. Meanwhile, we also provide traceable records for check.

2.Packing&Transportation

Wooden pallet packing or or to be defined by customer.

3. Leading time

For standard product, approximately 15 working days before delivery.

For customized product, approximately 20~30 working days before delivery.

Order quantity/customization requirements can also affect the leading time.

4.Warranty/ Payment terms

2 years of warranty at least.For the first order we normally accept T/T, 30%+70%. Regular customer payment terms to be negotiated by both parties.


jsd




Leave your messages

Related Products

x

Popular products

x
x