Three-Phase Transformer

Power transformers are classified by use: step-up (6.3kV/10.5kV or 10.5kV/110kV for power plants, etc.), communication (220kV/110kV or 110kV/10.5kV between substations), step-down (35kV/0.4kV or power distribution) 10.5kV/0.4kV).

Power transformers are classified according to the number of phases: single-phase and three-phase.

Power transformers are classified according to windings: double winding (each phase is installed on the same core, the primary and secondary windings are wound separately and insulated from each other), three winding (each phase has three windings, the primary and secondary windings are wound separately and insulated from each other), Autotransformer (a set of windings with center tap as primary or secondary output). A three-winding transformer requires the capacity of the primary winding to be greater than or equal to the capacity of the second and third windings. 

Product Details

Power transformers are classified by use: step-up (6.3kV/10.5kV or 10.5kV/110kV for power plants, etc.), communication (220kV/110kV or 110kV/10.5kV between substations), step-down (35kV/0.4kV or power distribution) 10.5kV/0.4kV).

Power transformers are classified according to the number of phases: single-phase and three-phase.

Power transformers are classified according to windings: double winding (each phase is installed on the same core, the primary and secondary windings are wound separately and insulated from each other), three winding (each phase has three windings, the primary and secondary windings are wound separately and insulated from each other), Autotransformer (a set of windings with center tap as primary or secondary output). A three-winding transformer requires the capacity of the primary winding to be greater than or equal to the capacity of the second and third windings. The percentages of the three winding capacities in the order of high voltage, medium voltage and low voltage are: 100/100/100, 100/50/100, 100/100/50. It is required that the second and third windings cannot operate at full load. Generally, the tertiary winding has a lower voltage and is mostly used for power supply in close areas or for connecting compensation equipment to connect three voltage levels. Autotransformer: There are two types: step-up or step-down. Because of its small loss, light weight and economical use, it is widely used in ultra-high voltage power grids. The commonly used model of small autotransformers is 400V/36V (24V), which is used to power security lighting and other equipment.

Industry-Specific Attributes


UseElectronic
PhaseThree
Coil StructureTOROIDAL
Coil NumberAUTOTRANSFORMER


Other Attributes


Place of OriginShandong, China
Brand NameJinshida
Model NumberSCB11-30~1600/,S11-30~1600
Input Voltage10kv
Product nameThree Phase Transformer
Rated capacity400kVA
Frequency50Hz/60Hz
StandardISO9001: 2008
NameHigh Fequency Transformer
Rated voltage10KV
Warranty24 Months
Secondary voltage10 KV
Cooling MethodONAN
Capacity400kva


Packaging and Delivery

Selling Units


Single item


Single package size


770X570X930 cm


Single gross weight


410.000 kg


Product Paramenters

10 Rated Power (kVA)

High Voltage (kv)

Low Voltage (kv)

Connection symbol

No-load loss(W)

On-load loss(W)

No load current (%)

30KVA

6.3KV

15KV

22KV

25KV

33KV

10KV

11KV

20KV

35KV

 

0.4

Ydn11

Yyno

570

4300

0.4

50KVA

80KVA

680

5140

0.45

100KVA

125KVA

810

30800

0.4

160KVA

200KVA

980

7500

0.4

250KVA

315KVA

1150

10300

0.35

400KVA

500KVA

1360

12000

0.3

630KVA

800KVA

1640

145000

0.6

1000KVA

1250KAV

1950

19140

0.6

1600KVA

2000KVA

2340

22220

0.5

2500KAV



Customized Various Models


Customized Various Models



Pruduct Details

Three-phase transformers and three-phase transformer groups can be connected in star, triangle, or zigzag shapes. They are represented by Y, D, and Z symbols on the high-voltage side, and by y, d, and z symbols on the low-voltage side. There is a neutral point lead out. High voltage is represented by YN and ZN symbols, and low voltage is represented by yn and zn symbols. According to different wiring combinations of three-phase windings, there are 12 types of wiring groups. However, for the convenience of manufacturing and use, our country originally stipulated 5 wiring groups: Y, Yn0 (Y/Y0-12); Y, Yn (Y/Y-12); YN, Yn (Y0/Y-12) ; Y, d11 (Y/△-11); YN, d11 (Y0/△-11).