Transformer is a device that uses the principle of electromagnetic induction to change AC voltage. Its main components are primary coil, secondary coil and iron core (magnetic core). The main functions are: voltage conversion, current conversion, impedance conversion, isolation, voltage stabilization (magnetic saturation transformer), etc.
Transformers can be divided according to their uses: distribution transformers, power transformers, fully sealed transformers, combined transformers, dry-type transformers, oil-immersed transformers, single-phase transformers, electric furnace transformers, rectifier transformers, reactors, anti-interference transformers, lightning protection Transformers, box-type transformer test transformers, corner transformers, high current transformers, excitation transformers, etc.
![2000KVA distribution transformer 2000KVA distribution transformer]()
Our Advantages
1. Suitable for CNC machines, airports, terminals, high-rise structures, and more.
2. By minimizing immersion in insulating oil, this design improves safety and lowers maintenance.
3. Provides 50% higher output capacity with forced air cooling (AF) for brief or emergency overloads and supports continuous operation at rated capacity with natural air cooling (AN).
4. Provides dependable performance under typical circumstances and has the capacity to handle brief overloads; however, extended overloads are not advised because of the increasing load loss and impedance voltage.
Sample Room
![Sample Room Sample Room]()
Product Process
![product process product process]()
Product Accessories
![product accessories product accessories]()
Product Parameters
Main Technical Parameters for 10KV SC ( B ) -30-2500TYPE |
| | | | | Short Circuit Inpendence
(%) | | |
sc(B)9 | sc(B)10 | sc(B)9 | sc(B)9 |
| | | | Dyn11 | | 220 | 190 | 750 | 710 |
| 310 | 270 | 1060 | 1000 |
| 420 | 370 | 1460 | 1380 |
| 450 | 400 | 1670 | 1570 |
| 530 | 470 | 1960 | 1850 |
| 610 | 540 | 2250 | 2130 |
| 700 | 620 | 2680 | 2530 |
| 810 | 720 | 2920 | 2760 |
| 990 | 880 | 3670 | 3470 |
| 1100 | 980 | 4220 | 3990 |
| 1310 | 1160 | 5170 | 4880 |
| 1510 | 1340 | 6220 | 5880 |
| 1460 | 1300 | 6310 | 5960 |
| 1710 | 1520 | 7360 | 6960 |
| 1990 | 1770 | 8610 | 8130 |
| 2350 | 2090 | 10260 | 9690 |
| 2760 | 2450 | 12400 | 11730 |
| 3400 | 3050 | 15300 | 14450 |
| 4000 | 3600 | 18180 | 17170 |
Packing and Shipping
![packing packing]()
Certificate
![certificate certificate]()
FAQ
1.Packing&Transportation
Wooden pallet packing or or to be defined by customer.
2. Leading time
For standard product, approximately 15 working days before delivery.
For customized product, approximately 20~30 working days before delivery.
Order quantity/customization requirements can also affect the leading time.
![jsd jsd]()