Dry type distribution transformer | 5MVA|8MVA|10MVA dry type transformer
Three-phase dry-type transformers are the main components of various power supplies and electrical equipment. It is a device that uses the principle of electromagnetic induction to change AC voltage. Three-phase dry distribution transformer is the main component of various power supplies and electrical equipment. It is a device that uses the principle of electromagnetic induction to change AC voltage. The main components are primary coil, secondary coil and iron core (magnetic core). In electrical equipment and wireless circuits, it is often used to increase and decrease voltage, match impedance, safety isolation, etc. In a generator, whether the coil moves through a magnetic field or the magnetic field moves through a fixed coil, an electric potential can be induced in the coil. In both cases, the value of the magnetic flux remains unchanged, but the number of magnetic fluxes intersecting the coil does. Change, this is the principle of mutual induction. Dry-type transformer is a device that uses electromagnetic mutual induction to transform voltage, current and impedance. The main components are primary coil, secondary coil and iron core (magnetic core). In electrical equipment and wireless circuits, it is often used to increase and decrease voltage, match impedance, safety isolation, etc. In a generator, whether the coil moves through a magnetic field or the magnetic field moves through a fixed coil, an electric potential can be induced in the coil. In both cases, the value of the magnetic flux remains unchanged, but the number of magnetic fluxes intersecting the coil does. Change, this is the principle of mutual induction. A transformer is a device that uses electromagnetic mutual induction to transform voltage, current and impedance.
Main Technical Parameters for 10KV SC ( B ) -30-2500TYPE |
| | | | | | | |
sc(B)9 | sc(B)10 | sc(B)9 | sc(B)9 |
| | | | Dyn11 | | 220 | 190 | 750 | 710 |
| 310 | 270 | 1060 | 1000 |
| 420 | 370 | 1460 | 1380 |
| 450 | 400 | 1670 | 1570 |
| 530 | 470 | 1960 | 1850 |
| 610 | 540 | 2250 | 2130 |
| 700 | 620 | 2680 | 2530 |
| 810 | 720 | 2920 | 2760 |
| 990 | 880 | 3670 | 3470 |
| 1100 | 980 | 4220 | 3990 |
| 1310 | 1160 | 5170 | 4880 |
| 1510 | 1340 | 6220 | 5880 |
| 1460 | 1300 | 6310 | 5960 |
| 1710 | 1520 | 7360 | 6960 |
| 1990 | 1770 | 8610 | 8130 |
| 2350 | 2090 | 10260 | 9690 |
| 2760 | 2450 | 12400 | 11730 |
| 3400 | 3050 | 15300 | 14450 |
| 4000 | 3600 | 18180 | 17170 |