Distribution transformer refers to a static electrical appliance used in distribution systems to transform AC voltage and current according to the law of electromagnetic induction to transmit AC power. China's transformer products can generally be divided into ultra-high voltage (750KV and above), ultra-high voltage (500KV) transformers, 220-110KV transformers, and 35KV and below transformers according to voltage levels. Distribution transformers usually refer to power transformers operating in the distribution network with a voltage level of 10-35KV and a capacity of 6300KVA and below to directly supply power to end users.
![Dry type distribution transformer2500KV·A Dry type distribution transformer2500KV·A]()
Our Advantages
1. Ideal for local lighting, high-rise buildings, airports, terminals, CNC machinery, and equipment.
2. Core and windings are not immersed in insulating oil, enhancing safety and reducing maintenance.
3. Offers both natural air cooling (AN) for continuous operation at rated capacity and forced air cooling (AF) to boost output capacity by 50% for intermittent or emergency overload operations.
4. Efficient operation under normal conditions, with the flexibility to handle temporary overloads, although not recommended for long-term continuous overload due to increased load loss and impedance voltage.
Sample Room
![sample sample]()
Product Process
![product process product process]()
Product Accessories
![product accessories product accessories]()
Product Parameters
Main Technical Parameters for 10KV SC ( B ) -30-2500TYPE |
| | | | | Short Circuit Inpendence
(%) | | |
sc(B)9 | sc(B)10 | sc(B)9 | sc(B)9 |
| | | | Dyn11 | | 220 | 190 | 750 | 710 |
| 310 | 270 | 1060 | 1000 |
| 420 | 370 | 1460 | 1380 |
| 450 | 400 | 1670 | 1570 |
| 530 | 470 | 1960 | 1850 |
| 610 | 540 | 2250 | 2130 |
| 700 | 620 | 2680 | 2530 |
| 810 | 720 | 2920 | 2760 |
| 990 | 880 | 3670 | 3470 |
| 1100 | 980 | 4220 | 3990 |
| 1310 | 1160 | 5170 | 4880 |
| 1510 | 1340 | 6220 | 5880 |
| 1460 | 1300 | 6310 | 5960 |
| 1710 | 1520 | 7360 | 6960 |
| 1990 | 1770 | 8610 | 8130 |
| 2350 | 2090 | 10260 | 9690 |
| 2760 | 2450 | 12400 | 11730 |
| 3400 | 3050 | 15300 | 14450 |
| 4000 | 3600 | 18180 | 17170 |
Packing and Shipping
![packing packing]()
Certificate
![certificate certificate]()
FAQ
1.On site/on line Production and Quality production supervision.Customer own the product supervision right, and for each important process during the manufacturing and testing (or to be defined by customer's request), by means of on site check or on line check. Meanwhile, we valso provide traceable records for check.
2.Packing&Transportation
Wooden pallet packing or or to be defined by customer.
3. Leading time
For standard product, approximately 15 working days before delivery.
For customized product, approximately 20~30 working days before delivery.
Order quantity/customization requirements can also affect the leading time.
4.Warranty/ Payment terms
2 years of warranty at least.For the first order we normally accept T/T, 30%+70%. Regular customer payment terms to be negotiated by both parties.
![jsd jsd]()