2500KVA Dry Type Transformer

1. Energy Saving and Low Noise: Advancements in new low-consumption silicon steel sheets, foil winding structures, stepped core joints, and computer optimization design will make future dry-type transformers more energy-efficient and quieter.

2. High Reliability: Continuous improvement in product quality and reliability will remain a primary focus.

3. Environmental Protection Certification: Adherence to European standard HD464 for climate resistance (C0, C1, C2), environment resistance (E0, E1, E2), and fire resistance (F0, F1, F2) will be pursued.

4. Large Capacity: Expansion from 50-2500kVA distribution transformers to 10000-20000kVA/35kV power transformers to meet increasing urban power demands.

5. Multi-Functional Combination: Development of multi-functional transformers integrating air cooling, protective shells, temperature computer interfaces, zero sequence transformers, power metering, closed busbars, and side outlets.


Product Details

Dry-type transformers have seen significant advancements in manufacturing technology, with future developments expected to focus on energy saving and low noise. New low-consumption silicon steel sheets, foil winding structures, stepped core joints, and environmental protection requirements will make these transformers more energy-efficient and quieter. High reliability will be a top priority, and environmental protection characteristics will be certified based on the European standard HD464. Large capacity transformers will be used in urban areas, residential communities, large factories, and mines, as urban power loads increase. Multi-functional combinations will be developed, from single transformers to multi-functional transformers with air cooling, protective shell, temperature computer interface, zero sequence transformer, power metering, closed busbar, and side outlet. These developments will contribute to the continued development of dry-type transformers.


2500KVA dry type transformer




Sample Room

Sample Room


Product Process


product process


Product Accessories


product accessories


Product Parameters


Main Technical Parameters for 10KV SC ( B ) -30-2500TYPE

Rated

Power

( kva )

High

Voltage

( kv )

H. V. Tap

range

LOW

Voltage

( kv )

Connection


symbol


Short 

Circuit 

Inpendence

(%) 

No-load loss

 ( KW )

On-load loss

 ( KW )

sc(B)9

sc(B)10

sc(B)9

sc(B)9

16

6

6.3

10

10.5

11

15

   22

   33

   35

±5%

±2x2.5%

0.4

Dyn11

       6

220

190

750

710

50

310

270

1060

1000

80

420

370

1460

1380

100

450

400

1670

1570

125

530

470

1960

1850

160

610

540

2250

2130

200

700

620

2680

2530

250

810

720

2920

2760

300

990

880

3670

3470

400

1100

980

4220

3990

500

1310

1160

5170

4880

630

1510

1340

6220

5880

630

1460

1300

6310

5960

800

1710

1520

7360

6960

1000

1990

1770

8610

8130

1250

2350

2090

   10260

9690

1600

2760

2450

12400

11730

2000

3400

3050

15300

14450

2500

4000

3600

   18180

17170


Packing and Shipping


packing


Certificate


certificate


FAQ

1.On site/on line Production and Quality production supervision.Customer own the product supervision right, and for each important process during the manufacturing and testing (or to be defined by customer's request), by means of on site check or on line check. Meanwhile, we valso provide traceable records for check.

2.Packing&Transportation

Wooden pallet packing or or to be defined by customer.


jsd


Leave your messages

Related Products

x

Popular products

x
x